5 - 5
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
5.1.2 Setting items for positioning parameters
The table below lists items set to the positioning parameters. Setting of positioning
parameters is similarly done for individual axes for all controls achieved by the QD75.
For details of controls, refer to PART 2. For details of setting items, refer to Section 5.2
"List of parameters".
Control
Major positioning control
Manual control
Position
control Other
control
Positioning parameter
OPR co
nt
ro
l
1-axi
s l
inear control
2/3/4-axi
s l
inear i
nterpol
ati
on control
1-axi
s fi
xed-feed control
2/3/4-axi
s fi
xed-feed control
2-axi
s ci
rcul
ar i
nterpol
ati
on control
1 to 4 axi
s speed control
S
peed-posi
tion or posi
tion-speed
control
C
urrent val
ue changi
ng
JUM
P
instr
uction, NOP
instr
uction,
LOOP
to LE
ND
Manual
pul
se generator operati
on
JOG operati
on
Inchi
ng operati
on
R
el
ated sub functi
on
Pr.1 Unit setting
–
Pr.2
No. of pulses per rotation (Ap)
(Unit: pulse)
Pr.3 Movement amount per rotation (Al)
Pr.4 Unit magnification (Am)
12.3.2
Pr.5 Pulse output mode
–
Pr.6 Rotation direction setting
–
B
asi
c parameters 1
Pr.7 Bias speed at start
– – –
–
Pr.8 Speed limit value
– – –
12.4.1
Pr.9 Acceleration time 0
– – –
B
asic
parameters 2
Pr.10 Deceleration time 0
– – –
12.7.6
Pr.11 Backlash compensation amount
– –
12.3.1
Pr.12 Software stroke limit upper limit value
–
– –
Pr.13 Software stroke limit lower limit value
–
– –
Pr.14 Software stroke limit selection
–
– –
Pr.15 Software stroke limit valid/invalid setting
–
–
–
–
–
–
12.4.3
Pr.16 Command in-position width
–
–
– – – –
12.7.5
Pr.17 Torque limit setting value
– –
12.4.2
Pr.18 M code ON signal output timing
–
– – –
12.7.3
Pr.19 Speed switching mode
–
– – – – – – –
Pr.20 Interpolation speed designation method
–
– – – – – –
Pr.21 Current feed value during speed control
–
–
–
–
– – – – –
Pr.22 Input signal logic selection
–
Pr.23 Output signal logic selection
–
Pr.24 Manual pulse generator input selection
–
–
–
–
–
–
–
–
– –
D
etai
led parameters 1
Pr.150
Speed-position function selection
–
–
–
–
–
– – – – –
: Always set
: Set as required
: Setting not possible
: Setting restricted
– : Setting not required. (This is an irrelevant item, so the set value will be ignored. If the value is the default value or within the setting range, there is no
problem.)
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......