15 - 44
MELSEC-Q
15 TROUBLESHOOTING
Classification
of warnings
Warning
code
Warning name
Warning
Operation status at warning
occurrence
500
Deceleration/stop
speed change
The speed change request is issued
during deceleration stop.
The speed change is not carried out.
501
Speed limit value
over
The new value exceeds the speed
limit value when the speed is
changed during operation.
• The speed is controlled with the
speed limit value.
• The "speed limiting flag" is turned
ON.
503
M code ON signal
ON start
The M code ON signal is turned ON
when the positioning data is
executed.
Continue executing the positioning
data.
505
No operation
termination setting
In the positioning by block starting,
the 50th point of the positioning start
data is set to CONTINUE.
The operation is terminated.
506
FOR to NEXT nest
construction
FOR to NEXT is nested.
508
Speed-position
switching (during
acceleration) signal
ON
The switching signal for speed-
position switching control (INC
mode) is turned ON during
acceleration.
The operation is continued.
Positioning
operation
509
Insufficient
remaining distance
• At a continuous operation interrupt
request, the distance required
deceleration stop is not long
enough.
• At a speed change request, the
remaining distance is shorter than
the distance required for speed
change.
• When a command speed is
changed:
Change to a value as near a new
speed value as possible.
• When a target position is changed:
Adjust the speed to a value as
near the command speed as
possible, and then change to a
target position.
(When the operation pattern is a
continuous path control, ignore the
operations stated above.)
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......