11 - 8
MELSEC-Q
11 MANUAL CONTROL
11.2.3 Setting the required parameters for JOG operation
The "Parameters" must be set to carry out JOG operation.
The following table shows the setting items of the required parameters for carrying out
JOG operation. When only JOG operation will be carried out, no parameters other than
those shown below need to be set. (Use the initial values or setting values within a
range where no error occurs for trouble-free operation.)
Setting item
Setting requirement
Factory-set initial value
(setting details)
Pr.1
Unit setting
3 (pulse)
Pr.2
No. of pulses per rotation (Ap) (Unit: pulse)
20000
Pr.3
Movement amount per rotation (Al) (Unit: pulse)
20000
Pr.4
Unit magnification (Am)
1 (1-fold)
Pr.5
Pulse output mode
1 (CW/CCW mode)
Pr.6
Rotation direction setting
0 (current value increases by
forward run pulse output)
Pr.7
Bias speed at start (Unit: pulse/s)
0
Pr.8
Speed limit value (Unit: pulse/s)
200000
Pr.9
Acceleration time 0 (Unit: ms)
1000
Pr.10
Deceleration time 0 (Unit: ms)
1000
Pr.11
Backlash compensation amount (Unit: pulse)
0
Pr.12
Software stroke limit upper limit value (Unit: pulse)
2147483647
Pr.13
Software stroke limit lower limit value (Unit: pulse)
–2147483648
Pr.14
Software stroke limit selection
0 (current feed value)
Pr.15
Software stroke limit valid/invalid setting
0 (valid)
Pr.17
Torque limit setting value (Unit: %)
300
Param
eters
Pr.23
Output signal logic selection
0 (Pulse output to drive unit is
negative logic.)
: Setting always required.
: Set according to requirements (Leave set to the initial value when not used.)
REMARK
•
Parameter settings work in common for all control using the QD75. When carrying
out other control ("major positioning control", "high-level positioning control", "OPR
positioning control"), the respective setting items must also be matched and set.
•
Parameters are set for each axis.
•
Refer to CHAPTER 5 "DATA USED FOR POSITIONING CONTROL" for setting
details.
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......