5 - 26
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
5.2.3 Detailed parameters 1
Setting value, setting range
Setting value buffer memory
address
Item
Value set with peripheral device
Value set with
sequence program
Default value
Axis 1 Axis 2 Axis 3 Axis 4
Pr.11
Backlash compensation
amount
The setting value range differs according to the "
Pr.1
Unit
setting".
Here, the value within the [Table 1] range is set.
[Table 1] on next page
0 17
167
317
467
Pr.12
Software stroke limit upper
limit value
2147483647
18
19
168
169
318
319
468
469
Pr.13
Software stroke limit lower
limit value
The setting value range differs according to the "
Pr.1
Unit
setting".
Here, the value within the [Table 2] range is set.
[Table 2] on next page
–2147483648
20
21
170
171
320
321
470
471
0 : Apply software stroke limit on current
feed value
0
Pr.14
Software stroke limit
selection
1 : Apply software stroke limit on
machine feed value
1
0 22
172
322
472
0 : Software stroke limit valid during JOG
operation,inching operation and
manual pulse generator operation
0
Pr.15
Software stroke limit
valid/invalid setting
1 : Software stroke limit invalid during
JOG operation ,inching operation and
manual pulse generator operation
1
0 23
173
323
473
Pr.11 Backlash compensation amount
The error that occurs due to backlash when moving the machine via gears can be
compensated.
When the backlash compensation amount is set, pulses equivalent to the
compensation amount will be output each time the direction changes during
positioning.
Workpiece
(moving body)
Worm gear
Backlash
(compensation amount)
Pr.44
OPR direction
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......