6 - 25
MELSEC-Q
6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
6.5.2 Start details setting program
This program sets which control, out of "OPR", "major positioning control" or "high-level
positioning control" to execute. For " high-level positioning control", "fast OPR", "speed-
position switching control" and "position-speed switching control", add the respectively
required sequence program.
(Refer to CHAPTER 10 for details on starting the " high-level positioning control.)
Procedures for setting the starting details
(1) Set the "positioning start No." corresponding to the control to be started in
"
Cd.3
Positioning start No.".
Buffer memory address
Setting item
Setting
value
Setting details
Axis 1 Axis 2 Axis 3 Axis 4
Cd.3
Positioning start No.
1 to 600
: Positioning data No.
9001 :
Machine
OPR
9002 :
Fast
OPR
9003
: Current value changing
9004 :
Simultaneous
start
7000 to 7004 : Block No.
(For "high-level positioning
control")
1500 1600 1700 1800
Refer to Section 5.7 "List of control data" for details on the setting details.
(2) For " high-level positioning control", set the "positioning start point No." of the
block to be started in "
Cd.4
Positioning starting point No.".
Buffer memory address
Setting item
Setting
value
Setting details
Axis 1 Axis 2 Axis 3 Axis 4
Cd.4
Positioning starting point
No.
1 to 50 : Point No. of block start data
1501 1601 1701 1801
Refer to Section 5.7 "List of control data" for details on the setting details.
(3) Set the following control data for "speed-position switching control (INC
mode)".
(Set "
Cd.23
Speed-position switching control movement amount change
register as required". Setting is not required in the ABS mode.)
Buffer memory address
Setting item
Setting
value
Setting details
Axis 1 Axis 2 Axis 3 Axis 4
Cd.23
Speed-position switching
control movement amount
change register
Set the new value when the position control's
movement amount is to be changed during
speed control.
1526
1527
1626
1627
1726
1727
1826
1827
Cd.24
Speed-position switching
enable flag
1
When "1" is set, the speed-position switching
signal will be validated.
1528 1628 1728 1828
Refer to Section 5.7 "List of control data" for details on the setting details.
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......