12 - 94
MELSEC-Q
12 CONTROL SUB FUNCTIONS
12.7.6 Acceleration/deceleration processing function
The "acceleration/deceleration processing function" adjusts the
acceleration/deceleration of each control to the acceleration/deceleration curve
suitable for devices.
Setting the acceleration/deceleration time changes the slope of the
acceleration/deceleration curve.
The following two methods can be selected for the acceleration/deceleration curve:
•
Trapezoidal acceleration/deceleration
•
S-curve acceleration/deceleration
The details shown below explain about the "acceleration/deceleration processing
function".
[1] "Acceleration/deceleration time 0 to 3" control details and setting
[2] "Acceleration/deceleration method setting" control details and setting
[1] "Acceleration/deceleration time 0 to 3" control details and setting
In the QD75, four types each of acceleration time and deceleration time can be
set. By using separate acceleration/deceleration times, control can be carried out
with different acceleration/deceleration times for positioning control, JOG
operation, OPR, etc.
Set the required values for the acceleration/deceleration time in the parameters
shown in the following table, and write them to the QD75.
The set details are validated when written to the QD75.
Setting item
Setting
value
Setting details
Factory-set
initial value
Pr.9 Acceleration time 0
1000
Pr.25 Acceleration time 1
1000
Pr.26 Acceleration time 2
1000
Pr.27 Acceleration time 3
Set the acceleration time at a value within the range
of 1 to 8388608ms.
1000
Pr.10 Deceleration time 0
1000
Pr.28 Deceleration time 1
1000
Pr.29 Deceleration time 2
1000
Pr.30 Deceleration time 3
Set the deceleration time at a value within the range
of 1 to 8388608ms.
1000
Refer to Section 5.2 "List of parameters" for setting details.
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......