12 - 72
MELSEC-Q
12 CONTROL SUB FUNCTIONS
12.7 Other functions
Other functions include the "step function", "skip function", "M code output function",
"teaching function", "command in-position function", "acceleration/deceleration
processing function", "pre-reading start function", "deceleration start flag function" and
"stop command processing for deceleration stop function". Each function is executed
by parameter setting or sequence program creation and writing.
12.7.1 Step function
The "step function" is used to confirm each operation of the positioning control one by
one.
It is used in debugging work for major positioning control, etc.
A positioning operation in which a "step function" is used is called a "step operation".
In step operations, the timing for stopping the control can be set. (This is called the
"step mode".) Control stopped by a step operation can be continued by setting "step
continue" (to continue the control)" in the "step start information".
The details shown below explain about the "step function".
[1] Relation between the step function and various controls
[2] Step mode
[3] Step start information
[4] Using the step operation
[5] Control details
[6] Control precautions
[7] Setting method
[1] Relation between the step function and various controls
The following table shows the relation between the "step function" and various
controls.
Control type
Step function
Step applicability
Machine OPR control
OPR control
Fast OPR control
Step operation not possible
1-axis linear control
2- to 4-axis linear interpolation control
1-axis fixed-feed control
2- to 4-axis fixed-feed control
(interpolation)
Position
control
2-axis circular interpolation control
Step operation possible
1- to 4-axis Speed control
Step operation not possible
Speed-position switching control
Position-speed switching control
Current value changing
Step operation possible
Major
positioning
control
Other
control JUMP instruction, NOP instruction,
LOOP to LEND
Step operation not possible
JOG operation, Inching operation
Manual
control
Manual pulse generator operation
Step operation not possible
: Set when required. : Setting not possible
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......