5 - 90
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
5.6.2 Axis monitor data
Storage item
Storage details
Md.20
Current feed value
The currently commanded address is stored.
(Different from the actual motor position during operation)
The current position address is stored.
If "degree" is selected as the unit, the addresses will have a ring structure for values
between 0 and 359.99999 degrees.
•
Update timing : 0.9ms (QD75P N/QD75D N), 1.8ms (QD75P /QD75D )
•
The OP address is stored when the machine OPR is completed.
•
When the current value is changed with the current value changing function, the
changed value is stored.
Md.21
Machine feed value
The address of the current position according to the machine coordinates will be
stored. (Different from the actual motor position during operation)
Note that the current value changing function will not change the machine feed
value.
Under the speed control mode, the machine feed value is constantly updated
always, irrespective of the parameter setting.
The value will not be cleared to "0" at the beginning of fixed-feed control.
Even if "degree" is selected as the unit, the addresses will not have a ring structure
for values between 0 and 359.99999 degrees.
•
Machine coordinates: Characteristic coordinates determined with machine
•
Update timing: 0.9ms (QD75P N/QD75D N), 56.8ms (QD75P /QD75D )
Md.22
Feedrate
The command output speed of the operating workpiece is stored. (May be different
from the actual motor speed during operation)
•
During interpolation operation, the speed is stored in the following manner.
Reference axis
: Composite speed or reference axis speed
(Set with
Pr.20
)
Interpolation axis : 0
•
Update timing: 0.9ms (QD75P N/QD75D N), 56.8ms (QD75P /QD75D )
Md.23
Axis error No.
When an axis error is detected, the error code corresponding to the error details is
stored.
•
The latest error code is always stored.
(When a new axis error occurs, the error code is overwritten.)
•
When "
Cd.5
Axis error reset" (axis control data) turns ON, the axis error No. is
cleared (set to 0).
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......