9 - 26
MELSEC-Q
9 MAJOR POSITIONING CONTROL
9.2 Setting the positioning data
9.2.1 Relation between each control and positioning data
The setting requirements and details for the setting items of the positioning data to be
set differ according to the "
Da.2
Control system".
The following table shows the positioning data setting items corresponding to the
different types of control. Details and settings for the operation of each control are
shown in Section 9.2.2 and subsequent sections.
(In this section, it is assumed that the positioning data setting is carried out using GX
Configurator-QP.)
Position control
Speed control
Major positioning control
Positioning data setting items
1-axis linear
control
2-axis linear
interpolation
control
3-axis linear
interpolation
control
4-axis linear
interpolation
control
1-axis fixed-feed
control
2-axis fixed-feed
control
3-axis fixed-feed
control
4-axis fixed-feed
control
2-axis circular
interpolation
control
1-axis, 2-axis,
3-axis, 4-axis
Speed control
Speed-
position
switching
control
Position-
speed
switching
control
Independent
positioning control
(Positioning complete)
Continuous positioning
control
Da.1
Operation
pattern
Continuous path
control
Da.2 Control system
Linear 1
Linear 2
Linear 3
Linear 4
Fixed-feed 1
Fixed-feed 2
Fixed-feed 3
Fixed-feed 4
Circular sub
Circular right
Circular left
Forward run
speed 1
Reverse run
speed 1
Forward run
speed 2
Reverse run
speed 2
Forward run
speed 3
Reverse run
speed 3
Forward run
speed 4
Reverse run
speed 4
Forward run
speed/posi-
tion
Reverse run
speed/posi-
tion
Forward run
position/speed
Reverse run
position/speed
Da.3 Acceleration time No.
Da.4 Deceleration time No.
Da.5 Axis to be interpolated
: 2 - a xi s –: 1, 3, 4-axis
– –
Da.6
Positioning address/movement
amount
–
Da.7 Arc address
–
–
– – –
Da.8 Command speed
Da.9 Dwell time
–
Da.10 M code
: Always set : Set as required
: Setting not possible (If setting is made, an error "Continuous path control not possible" (error code: 516) will occur at a start.)
– : Setting not required (Setting value is invalid. Use the initial values or setting values within a range where no error occurs.)
: The "ABS (absolute) system" or "INC (incremental) system" can be used for the control system.
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......