5 - 103
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Storage buffer
memory address
Reading the monitor value
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
Monitoring is carried out with a decimal display.
Monitor value
Storage value
0 to 255
0 832
932
1032 1132
Monitoring is carried out with a hexadecimal display.
Monitor value
Storage value
0 to FFFF
0000
H
833 933
1033 1133
Monitoring is carried out with a decimal display.
Monitor value
Storage value
1 to 50
0 834
934
1034 1134
Monitoring is carried out with a decimal display.
Monitor
value
Storage value
1 to 600, 9001 to 9003
0 835
935
1035 1135
Monitoring is carried out with a decimal display.
Monitor
value
Storage value
7000 to 7004
0 836
936
1036 1136
Monitoring is carried out with a decimal display.
Monitor
value
Storage value
1 to 600, 9001 to 9003
0 837
937
1037 1137
Information is stored in the following addresses:
Stored item
Positioning identifier
M code
Dwell time
Open
Command speed
Arc address
Da.1 to Da.5
Da.9
Da.8
Da.6
Da.7
Positioning address
Stored address (Monitor value)
Reference
Axis1 Axis2 Axis3
847
947
1047
846
946
1046
845
945
1045
844
944
1044
843
943
1043
842
942
1042
841
941
1041
840
940
1040
839
939
1039
838
938
1038
Da.10
Axis4
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
0
838
to
847
938
to
947
1038
to
1047
1138
to
1147
Monitoring is carried out with a decimal display.
Monitor value
Storage value
0: Status other than below
1: Status from deceleration
start to next operation
start or manual pulse
generator operation enable
0 899
999
1099 1199
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......