5 - 57
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Da.1 Operation pattern
The operation pattern designates whether positioning of a certain data No. is to be
ended with just that data, or whether the positioning for the next data No. is to be
carried out in succession.
[Operation pattern]
Positioning complete
Independent positioning control
(Positioning complete)
Positioning
continued
Continuous positioning with one start signal
Continuous positioning control
Continuous path positioning with speed change
Continuous path control
.............................................................................
.....
..........
1) Positioning complete..................... Set to execute positioning to the designated
address, and then complete positioning.
2) Continuous positioning control ..... Positioning is carried out successively in
order of data Nos. with one start signal.
The operation halts at each position
indicated by a positioning data.
3) Continuous path control................ Positioning is carried out successively in
order of data Nos. with one start signal.
The operation does not stop at each
positioning data.
Da.2 Control system
Set the "control system" for carrying out positioning control.
Note)
•
When "JUMP instruction" is set for the control system, the "
Da.9
Dwell time" and "
Da.10
M code" setting details will differ.
•
In case you selected "LOOP" as the control system, the "
Da.10
M code" should be set differently from other cases.
•
Refer to CHAPTER 9 "MAJOR POSITIONING CONTROL" for details
on the control systems.
•
If "degree" is set for "
Pr.1
Unit setting", circular interpolation control
cannot be carried out. (The error "Circular interpolation not possible"
(error code: 535) will occur when executed.)
Da.3 Acceleration time No.
Set which of "acceleration time 0 to 3" to use for the acceleration time during
positioning.
0 : Use the value set in "
Pr.9
Acceleration time 0".
1 : Use the value set in "
Pr.25
Acceleration time 1".
2 : Use the value set in "
Pr.26
Acceleration time 2".
3 : Use the value set in "
Pr.27
Acceleration time 3".
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......