5 - 102
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Storage item
Storage details
Md.41
Special start repetition
counter
•
This area stores the remaining number of repetitions during "repetitions" specific
to special starting.
•
The count is decremented by one (-1) at the loop end.
•
The control comes out of the loop when the count reaches "0".
•
This area stores "0" within an infinite loop.
Md.42
Control system repetition
counter
•
This area stores the remaining number of repetitions during "repetitions" specific
to control system.
•
The count is decremented by one (-1) at the loop start.
•
The loop is terminated with the positioning data of control method "LEND" after
the counter becomes "0".
Md.43
Start data pointer being
executed
•
This area stores a point No. (1 to 50) attached to the start data currently being
executed.
•
This area stores "0" after completion of a positioning operation.
Md.44
Positioning data No. being
executed
•
This area stores a positioning data No. attached to the positioning data currently
being executed.
•
This area stores "0" when the JOG/inching operation is executed.
Md.45
Block No. being executed
•
When the operation is controlled by "block start data", this area stores a block
number (7000 to 7004) attached to the block currently being executed.
•
At other times, this area stores "0".
Md.46
Last executed positioning
data No.
•
This area stores the positioning data No. attached to the positioning data that was
executed last time.
•
The value is retained until a new positioning operation is executed.
•
This area stores "0" when the JOG/inching operation is executed.
Md.47
Positioning data being
executed
•
The addresses shown to the right store details of the positioning data currently
being executed (positioning data No. given by
Md.44
).
Md.48
Deceleration start flag
•
"1" is stored when the constant speed status or acceleration status switches to the
deceleration status during position control whose operation pattern is "Positioning
complete".
•
"0" is stored at the next operation start or manual pulse generator operation
enable.
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......