12 - 91
MELSEC-Q
12 CONTROL SUB FUNCTIONS
12.7.5 Command in-position function
The "command in-position function" checks the remaining distance to the stop position
during the automatic deceleration of positioning control, and set a flag to 1. This flag is
called the "command in-position flag". The command in-position flag is used as a front-
loading signal indicating beforehand the completion of the position control.
The details shown below explain about the "command in-position function".
[1] Control details
[2] Control precautions
[3] Setting method
[4] Confirming the command in-position flag
[1] Control details
The following shows control details of the command in-position function.
(1) When the remaining distance to the stop position during the automatic
deceleration of positioning control becomes equal to or less than the value
set in "
Pr.16
Command in-position width", "1" is stored in the command
in-position flag (
Md.31
Status: b2).
(Command in-position width check)
Remaining distance
≤
" Pr.16 Command in-position width" setting value
Command in-position
width setting value
Positioning
V
t
ON
OFF
Command in-position flag
[ Md.31 Status : b2]
Fig. 12.46 Command in-position operation
(2) A command in-position width check is carried out every 0.9ms
(QD75P N/QD75D N) or 1.8ms (QD75P /QD75D ).
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......