5 - 2
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
5.1 Types of data
5.1.1 Parameters and data required for control
The parameters and data required to carry out control with the QD75 include the
"setting data", "monitor data" and "control data" shown below.
Setting data
(Data set beforehand according to the machine and application, and stored in the flash ROM.)
Parameters
Positioning
parameters
Basic parameters 1
Set according to the machine and applicable
motor when system is started up.
Note)
If the setting of the basic parameters 1 is incorrect, the rotation direction
may be reversed, or no operation may take place.
Basic parameters 2
Detailed parameters 1
Detailed parameters 2
Set according to the system configuration when
the system is started up.
Note)
Detailed parameters 2 are data items for using the QD75 functions to the fullest.
Set as required.
OPR basic parameters
OPR detailed parameters
Set the values required for carrying
out OPR control.
Positioning data
Positioning data
Set the data for "major positioning control".
Block start data
Set the block start data for "high-level positioning control".
Condition data
Set the condition data for "high-level positioning control".
Memo data
Set the condition judgment values for the condition
data used in "high-level positioning control".
to
) Pr.1
)
Pr.57
to
) Pr.1
)
Pr.42
,
OPR
parameters
to
) Pr.43
)
Pr.57
to
) Da.1
)
Da.10
to
) Da.11
)
Da.19
to
) Da.15
)
Da.19
to
) Da.11
)
Da.14
Block start data
Pr.150
The data is set with the sequence program or peripheral device.
In this chapter, the method using the peripheral device will be explained.
(Refer to "Point" on the next page.)
The basic parameters 1, detailed parameters 1, and OPR parameters become valid
when the PLC READY signal [Y0] turns from OFF to ON. Note, however, that the
only valid value of the "
Pr.5
Pulse output mode" is the value at the moment when
the PLC READY signal [Y0] turns from OFF to ON for the first time after the power
is switched ON or the CPU module is reset. Once the PLC READY signal [Y0] has
been turned ON, the value will not be reset even if another value is set to the
parameter and the PLC READY signal [Y0] is turned from OFF to ON.
Even when the PLC READY signal [Y0] is ON, the values or contents of the
following can be changed: basic parameters 2, detailed parameters 2, positioning
data, and block start data.
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......