14 - 21
MELSEC-Q
14 DEDICATED INSTRUCTIONS
[Functions]
(1) This dedicated instruction is used to return the setting data set in the QD75 buffer
memory and flash ROM to their factory-set data (initial values).
Initialized setting data
Parameters (
Pr.1
to
Pr.57
,
Pr.150
)
Positioning data (No. 1 to No. 600)
Block start data (No. 7000 to 7004)
(2) The ZP.PINIT instruction completion can be confirmed using the complete devices
((D)+0) and ((D)+1).
(a) Complete device ((D)+0)
This device is turned ON by the END processing of the scan for which
ZP.PINIT instruction is completed, and turned OFF by the next END
processing.
(b) Complete state display device ((D)+1)
This device is turned ON and OFF according to the state in which ZP.PINIT
instruction is completed.
• When completed normally
: Kept unchanged at OFF.
• When completed abnormally : This device is turned ON by the END
processing of the scan for which ZP.PINIT
instruction is completed, and turned OFF by
the next END processing. (same ON/OFF
operation as complete device).
END
processing
END
processing
END
processing
END
processing
OFF
OFF
OFF
ON
ON
ON
When
completed
abnormally
When
completed normally
1 scan
ZP.PINIT instruction
execution completion
Sequence program
ZP.PINIT instruction
Complete device
Complete state display
device
[Errors]
(1) When a dedicated instruction is completed abnormally, the error complete signal
((D)+1) is turned ON, and the error code is stored in the complete status ((S)+1).
Check and take measures against the error referring to Section 15.3 "List of error
codes".
[Precautions]
(1) The ZP.PINIT instruction can only be executed when the QD75 READY signal
(X0) is turned OFF.
When the QD75 READY signal is turned ON, the ZP.PINIT instruction cannot be
executed.
Before executing the ZP.PINIT instruction, turn OFF the PLC READY signal (Y0)
and then turn OFF the QD75 READY signal.
(2) When the remote I/O station (Q Corresponding MELSECNET/H network remote
I/O module) is used, the dedicated instruction (ZP.PINIT) is unusable.
: For details of the remote I/O station, refer to Q Corresponding MELSECNET/H
Network System Reference Manual (Remote I/O Network).
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......