5 - 8
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
5.1.4 Setting items for positioning data
Positioning data must be set for carrying out any "major positioning control". The table
below lists the items to be set for producing the positioning data.
One to 600 positioning data items can be set for each axis.
For details of the major positioning controls, refer to CHAPTER 9 "MAJOR
POSITIONING CONTROL". For details of the individual setting items, refer to Section
5.3 "List of positioning data".
Major positioning control
Position control
Other control
Positioning data
1-axi
s l
inear control
2/3/4-axi
s l
inear
in
terpol
ati
on control
1-axi
s fi
xed-feed control
2/3/4-axi
s fi
xed-feed control
2-axi
s ci
rcul
ar i
nterpol
ati
on
control
1 to 4 axi
s speed control
S
peed-posi
tion sw
itchi
ng
control
P
osi
tion-speed sw
itchi
ng
control
NOP in
str
uctio
n
C
urrent val
ue changi
ng
JUM
P
instr
uction
LOOP
LE
ND
Independent
positioning
control
–
– –
–
Continuous
positioning
control
–
– –
–
Da.1
Operation
pattern
Continuous path
control
–
– –
–
Da.2
Control system
Linear 1
Linear 2
Linear 3
Linear 4
Fixed-
feed 1
Fixed-
feed 2
Fixed-
feed 3
Fixed-
feed 4
Circular
sub
Circular
right
Circular
left
Forward
run speed 1
Reverse run
speed 1
Forward
run speed 2
Reverse run
speed 2
Forward
run speed 3
Reverse run
speed 3
Forward
run speed 4
Reverse run
speed 4
Forward
run
speed/
position
Reverse
run
speed/
position
Forward
run
position/
speed
Reverse
run
position/
speed
NOP
instruction
Current
value
changing
JUMP
instruction
LOOP LEND
Da.3
Acceleration time No.
– – – –
–
Da.4
Deceleration time No.
– – – –
–
Da.5
Axis to be
interpolated
: 2 axes
– : 1/3/4 axes
– – – – – – – – – –
–
Da.6
Positioning address/
movement amount
–
–
New
address
– –
–
Da.7
Arc address
– –
– –
– – – – –
–
Da.8
Command speed
–
– – –
–
Da.9
Dwell time
(JUMP destination
positioning data No.)
–
–
JUMP
destination
positioning
data No.
– –
Da.10
M code
(JUMP condition data No.)
–
JUMP
condition
data No.
No. of
LOOP to
LEND
repetitions
–
: Always set
: Set as required
: Setting not possible
– : Setting not required.
(This is an irrelevant item, so the set value will be ignored. If the value is the default value or within the setting range, there is no problem.)
: Two control systems are available: the absolute (ABS) system and incremental (INC) system.
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......