1 - 23
MELSEC-Q
1 PRODUCT OUTLINE
1.3 Restrictions with a system using a stepping motor
Note the following restrictions applicable to a system that uses a stepping motor:
(1) For the system that uses a stepping motor, executing the S-curve
acceleration/deceleration may cause step-out.
Before using the S-curve acceleration/deceleration, confirm that step-out does
not occur.
(2) Although setting the bias speed at start is required by the characteristics of the
stepping motor, the setting of the bias speed at start is disabled for circular
interpolation control.
1.4 Function additions/modifications according to function version B
POINT
When it is desired to check the following items, refer to the corresponding
explanation sections.
How to check the function version and SERIAL No. (Refer to Section 2.4)
The following function additions/modifications according to the function version B of the
QD75:
Function Outline
Reference
Multiple CPU compatible function
Refer to QCPU User's Manual (Multiple CPU System).
Speed-position switching control (ABS mode)
Function which starts the axis under speed control,
switches to position control at the external command
signal input, then positions the axis to a stop at the
designated address.
Section 9.2.17
Pre-reading start function
Function which shortens virtual start time.
Section 12.7.7
External I/O signal monitor function
Function which monitors the external I/O signal monitor
information in the module's detailed information which
can be displayed on the system monitor of GX
Developer 1.
Section 13.5
Deceleration start flag function 2
Function that turns ON the flag when the constant
speed status or acceleration status switches to the
deceleration status during position control whose
operation pattern is "Positioning complete".
Section 12.7.8
Stop command processing for deceleration stop
function 3
Function that selects a deceleration curve when a stop
cause occurs during deceleration stop processing to
speed 0.
Section 12.7.9
1: For the QD75P /QD75D , this function is available in GX Developer (SW6D5C-GPPW-E or later). For details, refer to
GX Developer Operating Manual.
For the QD75P N/QD75D N, external I/O signals cannot be monitored on GX Developer. Use the system monitor of
GX Works2. For details on the system monitor of GX Works2, refer to GX Works2 Version 1 Operating Manual
(Common).
2: For the QD75P /QD75D , this function is available for modules whose serial No. (first five digits) is "03042" or later.
3: For the QD75P /QD75D , this function is available for modules whose serial No. (first five digits) is "05072" or later.
Summary of Contents for Melsec-Q QD75D1
Page 1: ......
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Page 292: ...MEMO ...
Page 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Page 857: ......
Page 858: ......