1594
1
3
S
yst
em
O
p
er
at
ion and Man
agem
ent
(a) moduleConfigBlade group (3/25)
No.
Object
identifier
OID
Syntax
Access
Description
23
bladeInfoMa
xCurrency
.1.3.6.1.4.1
.116.5.39.2
.2.1.1.20
Integer32
RO
Shows the max current value of
the server blade installed in the
slot shown in #5. This value is
shown using the unit of 0.1A.
(*4)(*8)
24
bladeInfoMa
xPower
.1.3.6.1.4.1
.116.5.39.2
.2.1.1.21
Integer32
RO
Shows the rated power value of
the server blade installed in the
slot shown in #5. This value is
shown using the unit of 1W.
(*4)(*8)
25
bladeInfoAm
bientTempHi
gher
.1.3.6.1.4.1
.116.5.39.2
.2.1.1.22
Integer32
RO
Shows the upper temperature
threshold value of inlet air for
warning to the server blade
installed in the slot shown in #5.
This value is shown as 1 for
0.1°C. (*4)
26
bladeInfoAm
bientTempLo
wer
.1.3.6.1.4.1
.116.5.39.2
.2.1.1.23
Integer32
RO
Shows the lower temperature
threshold value of inlet air for
warning to the server blade
installed in the slot shown in #5.
This value is always shown as 0.
27
bladeInfoCP
U0TempHigh
er
.1.3.6.1.4.1
.116.5.39.2
.2.1.1.24
Integer32
RO
Shows the upper temperature
threshold value of CPU for
warning in the server blade
installed in the slot shown in #5.
This value is shown as 1 for
0.1°C. (*4)
28
bladeInfoCP
U0TempLow
er
.1.3.6.1.4.1
.116.5.39.2
.2.1.1.25
Integer32
RO
Shows the lower temperature
threshold value of CPU for
warning in the server blade
installed in the slot shown in #5.
This value is always shown as 0.
29
bladeInfoCP
U1TempHigh
er
.1.3.6.1.4.1
.116.5.39.2
.2.1.1.26
Integer32
RO
Shows the upper temperature
threshold value of CPU for
warning in the server blade
installed in the slot shown in #5.
This value is shown as 1 for
0.1°C. (*4)
30
bladeInfoCP
U1TempLow
er
.1.3.6.1.4.1
.116.5.39.2
.2.1.1.27
Integer32
RO
Shows the lower temperature
threshold value of CPU for
warning in the server blade
installed in the slot shown in #5.
This value is always shown as 0.
(*1) “Not install” is shown if no server blade is installed; “Cannot get data” is shown if the
data cannot be obtained.
(*2) “Not install” is shown if no server blade is installed; “Cannot get data” is shown if the
server blade data cannot be obtained. “Not support” is shown as the response in this
equipment.
(*3) The response is “-1” if no server blade is installed, or if no partition exists.
(*4) The response is “0” if no server blade or no processor is installed.
(*8) With SMP configuration, when the primary blade location is specified in a partition, the
values of the entire partition are displayed; when a blade location other than the primary
one is specified, “0” is displayed.
Summary of Contents for Compute Blade 2000
Page 1: ...MK 99BDS2K001 16 Hitachi Compute Blade 2000 User s Guide ...
Page 42: ...xlii Precautions for Safe Use Rear View of A1 A2 Chassis ...
Page 43: ...xliii Precautions for Safe Use Rear View of A2 Chassis ...
Page 44: ...xliv Precautions for Safe Use Server Blade ...
Page 45: ...xlv Precautions for Safe Use I O Slot Expansion Unit ...
Page 46: ...xlvi Precautions for Safe Use I O Module ...
Page 47: ...xlvii Precautions for Safe Use AC Power Input Module ...
Page 51: ...li How to Use the Manuals This page is intentionally left blank ...
Page 61: ...10 1 Before Use ...
Page 64: ...13 2 How to Use the System Equipment Rear view of A1 chassis Rear view of A2 chassis ...
Page 93: ...42 2 How to Use the System Equipment ...
Page 123: ...72 3 Connecting the System Equipment and Powering On ...
Page 272: ...221 5 Server Blade Setup 3 Check Del and click Go The following screen appears 4 Click Yes ...
Page 345: ...294 5 Server Blade Setup 12 Click Next The following screen appears ...
Page 351: ...300 5 Server Blade Setup 3 Check Delete and click Go The following screen appears 4 Click Yes ...
Page 426: ...375 5 Server Blade Setup 3 Check Delete and click Go The following screen appears 4 Click Yes ...
Page 430: ...379 5 Server Blade Setup 3 Click Go Hotspare is set to the specified hard disk ...
Page 479: ...428 5 Server Blade Setup ...
Page 717: ...666 6 Management Module Settings Details of a physical partition ...
Page 722: ...671 6 Management Module Settings Server blade details view ...
Page 723: ...672 6 Management Module Settings ...
Page 732: ...681 6 Management Module Settings Management module details view ...
Page 745: ...694 6 Management Module Settings Optional Physical WWN list view ...
Page 748: ...697 6 Management Module Settings Optional Physical WWN initialization view ...
Page 751: ...700 6 Management Module Settings ...
Page 754: ...703 6 Management Module Settings Power status details view ...
Page 767: ...716 6 Management Module Settings ...
Page 768: ...717 6 Management Module Settings ...
Page 769: ...718 6 Management Module Settings ...
Page 814: ...763 6 Management Module Settings Power status trend view partition ...
Page 817: ...766 6 Management Module Settings Access log display view ...
Page 819: ...768 6 Management Module Settings WWN change log display view ...
Page 879: ...828 7 Configuring the LAN Switch Module Link aggregation adding editing screen ...
Page 899: ...848 8 Configuring the 10 Gb DCB Switch Module ...
Page 919: ...868 10 Configuring the Fibre Channel Switch Module ...
Page 1535: ...1484 12 Logical partitioning manager ...
Page 1877: ...1826 14 14 When You Need Help ...
Page 1925: ...16 Glossary ...