The XTR2 Field Programmer allows you to connect a PC to the 

XTR2 control via USB for field programming and diagnostic 

data download. The Field Programmer application features a 

simple graphical interface for easy control programming.

SOFTWARE INSTALLATION

The following hardware and software is required to install the 

XTR2 Field Programmer application:

•  Licensed copy of XTR2 Field Programmer installation file

Minimum system requirements

Operating 

system

Windows 7, Windows 8, Windows 8.1, Windows 10

CPU

1 GHz

Memory

512 GB RAM

Hard drive

2 GB of free space

CAUTION

 Do not connect XTR2 before installing the field 

programmer.

T

o install the XTR2 Field Programmer application:

1.  Locate the 

FPA_Installer.exe

 file included with your Field 

Programmer installation package. Double-click on the file 

to begin installation. 

2.  The InstallShield Wizard will appear, and will walk you 

through the rest of the installation process. Click 

Next

 

to continue, and follow the prompts to complete the 

installation.

FLECK

 

XTR2 FIELD PROGRAMMER

INSTALLATION AND OPERATION INSTRUCTIONS

4.  Launch the Field Programmer application by double-

clicking the desktop icon or selecting the Start menu item. 

The Field Programmer Master Programming Settings 

window appears.

Figure 2  Field Programmer Master Programming Settings

FIELD PROGRAMMER FEATURES

The Field Programmer application features an easy to use 

graphical interface designed to complement the look and feel 

of the XTR2 control. 
The main screen used when programming is the Master 

Programming Setting screen (see Figure 2). This screen can 

be divided into three main interface areas: the Master Settings 

Menu, Data Transfer Icons, and the Programming area.

Master Settings Menu

The Master Settings Menu organizes master settings 

parameters into several categories, listed below. Click the 

menu item to display the parameter set. 

CAUTION

 Improperly adjusting master settings may cause 

the system to operate incorrectly. 

NOTE: Please refer to the 

Fleck 5800 or 5810/5812 XTR2 Service 

Manuals

 for complete master settings procedures and 

parameter descriptions.

•  format

: Contains initial control setup and format 

settings.

•  valve

: Contains settings specific to the valve and system.

•  regen

: Contains settings specific to the selected 

regenerant flow.

•  relay

: Contains auxiliary relay settings.

•  diagnostic

: Displays diagnostic information that can be 

downloaded from the control.

•  summary

: Displays a summary of all programmed 

settings.

Control 

Successfully 

Connected

Data Transfer Icons

Settings Menu

Master Settings

Figure 1  Field Programmer InstallShield Wizard

3.  When installation is complete, the Pentair Field 

Programmer shortcut will appear on your desktop and in 

your Start menu. 

  

waterpurification.pentair.com

Summary of Contents for FLECK XTR2

Page 1: ...rammer Master Programming Settings FIELD PROGRAMMER FEATURES The Field Programmer application features an easy to use graphical interface designed to complement the look and feel of the XTR2 control The main screen used when programming is the Master Programming Setting screen see Figure 2 This screen can be divided into three main interface areas the Master Settings Menu Data Transfer Icons and t...

Page 2: ...s parameter descriptions Updating Master Settings Field Programmer Master Settings are displayed with a label describing the setting as well as its current value Click either the label or the settings value to select a setting for editing Settings change from blue to light gray when selected Settings that are displayed in dark gray are not editable based on current programming settings Click anywh...

Page 3: ...ars on the control screen when a successful connection to the PC has been made NOTE Pressing the Settings button on the XTR2 control will disconnect the control from the PC and return the display to the Master Settings screen Do not press until you are ready to disconnect 8 If you have not already done so launch the Field Programmer software on your PC by double clicking on the Pentair Field Progr...

Page 4: ...our saved configuration file is stored Select the file and click the Open button The saved configuration is loaded into the Field Programmer application 3 Upload the saved configuration to the control by following the procedure titled Uploading Programmed Settings to the XTR2 Control above Disconnecting from the Control When all programming is complete the XTR2 control will display a message stati...

Reviews: