Performance Monitor
PowerPC e500 Core Family Reference Manual, Rev. 1
Freescale Semiconductor
7-15
Com:37 Stores completed and allocated to
DLFB
Nonspec Applies to same class of instructions as stores translated.
Com:38 Touches translated and allocated to
DLFB
Spec
Applies to same class of instructions as touches translated.
Com:39 Stores completed
Nonspec Cacheable
st
* or
evst
* micro-ops completed. (Applies to the same
class of instructions as stores translated.)
1,2
Com:40 Data L1 cache locks
Nonspec Cache lines locked in the data L1 cache. (Counts a lock even if an
overlock condition occurs.)
Com:41 Data L1 cache reloads
Spec
Counts cache reloads for any reason. Typically used to determine
data cache miss rate (along with loads/stores completed).
Com:42 Data L1 cache castouts
Spec
Does not count castouts due to
dcbf
.
Data Side Replay Conditions: Times Detected
Com:43 Load miss with DLFB full.
Spec
Counts number of stalls; Com:51 counts cycles stalled.
Com:44 Load miss with load queue full.
Spec
Counts number of stalls; Com:52 counts cycles stalled.
Com:45 Load guarded miss when the load is
not yet at the bottom of the CQ.
Spec
Counts number of stalls; Com:53 counts cycles stalled.
Com:46 Translate a store when the store
queue is full.
Spec
Counts number of stalls; Com:54 counts cycles stalled.
Com:47 Address collision.
Spec
Counts number of stalls; Com:55 counts cycles stalled.
Com:48 Data MMU miss.
Spec
Counts number of stalls; Com:56 counts cycles stalled.
Com:49 Data MMU busy.
Spec
Counts number of stalls; Com:57 counts cycles stalled.
Com:50 Second part of misaligned access
when first part missed in cache.
Spec
Counts number of stalls; Com:58 counts cycles stalled.
Data Side Replay Conditions: Cycles Stalled
Com:51 Load miss with DLFB full.
Spec
Counts cycles stalled; Com:43 counts number of stalls.
Com:52 Load miss with load queue full.
Spec
Counts cycles stalled; Com:44 counts number of stalls.
Com:53 Load guarded miss when the load is
not yet at the bottom of the CQ.
Spec
Counts cycles stalled; Com:45 counts number of stalls.
Com:54 Translate a store when the store
queue is full.
Spec
Counts cycles stalled; Com:46 counts number of stalls.
Com:55 Address collision.
Spec
Counts cycles stalled; Com:47 counts number of stalls.
Com:56 Data MMU miss.
Spec
Counts cycles stalled; Com:48 counts number of stalls.
Com:57 Data MMU busy.
Spec
Counts cycles stalled; Com:49 counts number of stalls.
Com:58 Second part of misaligned access
when first part missed in cache.
Spec
Counts cycles stalled; Com:50 counts number of stalls.
Fetch, Instruction Cache, Instruction Line Fill Buffer (ILFB), and Instruction Prefetch Events
Com:59 Instruction L1 cache locks
Nonspec Counts cache lines locked in the instruction L1 cache. (Counts a lock
even if an overlock occurs.)
Table 7-10. Performance Monitor Event Selection (continued)
Number
Event
Spec/
Nonspec
Count Description
Summary of Contents for PowerPC e500 Core
Page 1: ...PowerPC e500 Core Family Reference Manual Supports e500v1 e500v2 E500CORERM Rev 1 4 2005...
Page 36: ...PowerPC e500 Core Family Reference Manual Rev 1 xxxvi Freescale Semiconductor...
Page 38: ...PowerPC e500 Core Family Reference Manual Rev 1 Part I 2 Freescale Semiconductor...
Page 332: ...PowerPC e500 Core Family Reference Manual Rev 1 Part II 2 Freescale Semiconductor...
Page 530: ...Opcode Listings PowerPC e500 Core Family Reference Manual Rev 1 D 50 Freescale Semiconductor...
Page 534: ...PowerPC e500 Core Family Reference Manual Rev 1 E 4 Freescale Semiconductor Revision History...