PROTNA
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Protection Unit Not Available (PROTNA) alarm is raised when a standby control card is not available.
Clear the PROTNA Alarm
SUMMARY STEPS
1.
Ensure that the standby control card is installed and provisioned in the chassis.
DETAILED STEPS
Ensure that the standby control card is installed and provisioned in the chassis.
PROV-MISMATCH
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Provisioning Mismatch alarm is raised against a PPM connector on MXP_2.5G_10E, MXP_2.5G_10E_C,
MXP_2.5G_10E_L, MXP_2.5G_10G, MXP_MR_2.5G, MXPP_MR_2.5G, TXP_MR_2.5G, TXP_MR_10E,
TXP_MR_10E_C, TXP_MR_10E_L, TXPP_MR_2.5G, GE_XP, 10GE_XP, ADM-10G, OTU2_XP, MR-MXP,
WSE, 10x10G-LC, 100G-LC-C, 100G-CK-LC, 200G-CK-LC, 100GS-CK-LC, 400G-XP, CFP-LC, AR-XP,
AR-MXP, AR-XPE, 40G-MXP, 40G-TXP, 40E-MXP, and 40E-TXP cards under one of the following
circumstances:
• The physical PPM range or wavelength does not match the provisioned value. PPMs have static wavelength
values which must match the wavelengths provisioned for the card in the case of non-DWDM PPMs.
• The PPM reach (loss) value does not meet the reach value needed for the card.
• The reach of the inserted PPM does not match the physical PPM.
This alarm is raised on GE_XP and 10GE_XP cards, if the following settings are configured:
• Double Add and Translate Add selective modes
• CVLAN Ingress CoS
• MAC address learning on SVLAN
Until this alarm is cleared, provisioning on the GE_XP and 10GE_XP cards is not possible
The Provisioning Mismatch (PROV-MISMATCH) alarm is raised against a TNC/TNCS/TNCE/TNCS-O
card under one of the following circumstances:
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
363
Alarm Troubleshooting
PROTNA