If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
INHSWWKG
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Inhibit Switch To Working Request on Equipment condition occurs on traffic cards when the ability to
switch to working has been disabled. If the card is part of a 1:1 or 1+1 protection scheme, traffic remains
locked onto the protect system. If the card is part of a 1:N protection scheme, traffic can be switched between
protect cards when the switch to working is disabled.
Clear the INHSWWKG Condition
SUMMARY STEPS
1.
If the condition is raised against a 1+1 port, complete the
Initiate a 1+1 Manual Switch Command, on
procedure.
2.
If it is raised against a 1:1 card, complete the
Initiate a 1:1 Card Switch Command, on page 445
procedure
to switch it back.
DETAILED STEPS
Step 1
If the condition is raised against a 1+1 port, complete the
Initiate a 1+1 Manual Switch Command, on page 444
procedure.
Step 2
If it is raised against a 1:1 card, complete the
Initiate a 1:1 Card Switch Command, on page 445
procedure to switch it
back.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
INCOMPATIBLE-SEND-PDIP
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: SYSTEM
The Incompatible Software alarm is raised when CTC send PDI-P provisioning differs from the host node's
provisioning.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
238
Alarm Troubleshooting
INHSWWKG