• Mode conversion from ANSI to ETSI.
Clear the NODE-FACTORY-MODE Alarm
Reset to the default setting using 'Rebuild DB' option.
(or)
Restore the database.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
NOT-AUTHENTICATED
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: SYSTEM
The NOT-AUTHENTICATED alarm is raised by CTC (not by the NE) when CTC fails to log into a node.
This alarm only appears in CTC where the login failure occurred. This alarm differs from the
alarm, because INTRUSION-PSWD occurs when a user exceeds the login
failures threshold.
The NOT_AUTHENTICATED alarm is also raised, when CTC nodes in the network have R10.6 packages
and earlier and password policy is less than 80 characters.
NOT-AUTHENTICATED is an informational alarm and is resolved when CTC successfully logs into the
node.
Note
OCHNC-BDI
Default Severities: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Objects: OTS
The Optical Channel Network Connection (OCHNC) Backward Defect Indication(BDI) alarm is raised when
an OCHNC signal is interrupted along the circuit path and the system is not able to recover it.
Clear the OCHNC-BDI Alarm
This alarm is cleared automatically when the interrupt is rectified and the signal flows properly.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
311
Alarm Troubleshooting
Clear the NODE-FACTORY-MODE Alarm