Clear the EFM-RFI-DG Alarm
SUMMARY STEPS
1.
To clear the EFM-RFI-DG alarm, check if the peer is administratively disabled. If it is, move the port to
IS state.
DETAILED STEPS
To clear the EFM-RFI-DG alarm, check if the peer is administratively disabled. If it is, move the port to IS state.
If the peer device is not an GE-XP or 10GE-XP card, consult the peer device manual to find the scenarios under
which the EFM-RFI-DG alarm is raised.
Note
EFM-RFI-LF
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Object: GE
The EFM Remote Failure Indication Link Fault (EFM-RFI-LF) alarm indicates that the peer interface has a
carrier loss.
Clear the EFM-RFI-LF Alarm
SUMMARY STEPS
1.
Clear the EHIBATVG and CARLOSS alarms on the peer Ethernet interface.
DETAILED STEPS
Clear the EHIBATVG and CARLOSS alarms on the peer Ethernet interface.
If the peer device is not a GE_XP or 10GE_XP card, consult the user documentation of the peer device to
understand scenarios under which the alarm is raised.
Note
EFM-RLBK
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Objects: GE
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
172
Alarm Troubleshooting
Clear the EFM-RFI-DG Alarm