AUTO-SENSE-DSBLD
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: PPM
The AUTO-SENSE-DSBLD alarm is raised when the port is configured as an AUTO port, but auto-sensing
is disabled.
Clear the AUTO-SENSE-DSBLD Alarm
SUMMARY STEPS
1.
Clear the AUTO-SENSE-DSBLD alarm with either of these procedures:
DETAILED STEPS
Clear the AUTO-SENSE-DSBLD alarm with either of these procedures:
a) Enable auto-sensing.
1.
Login to CTC.
2.
In node view (single-shelf mode) or shelf view (multishelf view), double-click the AR_MXP or AR_XP card
where you want to enable auto-sensing.
3.
Click the
Provisioning
>
Line
>
Auto Ports
tabs.
4.
Check the
Auto Sensing
check box.
b) Delete the auto port.
1.
Login to CTC.
2.
In node view (single-shelf mode) or shelf view (multishelf view), double-click the AR_MXP or AR_XP card
where you want to delete the auto port.
3.
Click the
Provisioning
>
Pluggable Port Modules
tabs.
4.
In the Pluggable Port Modules area, select the auto PPM that you want to delete and click
Delete
.
5.
Click
Yes
. The auto port is deleted.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
AUTORESET
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
132
Alarm Troubleshooting
AUTO-SENSE-DSBLD