Logical Object: ENVALRM
A Failure Detected External to the NE alarm occurs because an environmental alarm is present. For example,
a door could be open or flooding could have occurred.
Clear the EXT Alarm
SUMMARY STEPS
1.
In node view (single-shelf mode) or shelf view (multishelf mode), double-click the AIC-I card to open
the card view.
2.
Double-click the
Maintenance
>
External Alarms
tabs.
3.
Follow your standard operating procedure to remedy environmental conditions that cause alarms. The
alarm clears when the situation is remedied.
DETAILED STEPS
Step 1
In node view (single-shelf mode) or shelf view (multishelf mode), double-click the AIC-I card to open the card view.
Step 2
Double-click the
Maintenance
>
External Alarms
tabs.
Step 3
Follow your standard operating procedure to remedy environmental conditions that cause alarms. The alarm clears when
the situation is remedied.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
FAILTOSW (2R, EQPT, ESCON, FC, GE, ISC, OCN/STMN, TRUNK,
OTS)
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Objects: 2R, EQPT, ESCON, FC, GE, ISC, OCN/STMN, TRUNK, OTS
The Failure to Switch to Protection Facility condition for MXP and TXP client ports occurs in a Y-cable
protection group when a working or protect facility switches to its companion port by using a MANUAL
command. For example, if you attempt to manually switch traffic from an unused protect port to an in-service
working port, the switch will fail (because traffic is already present on the working port) and you will see the
FAILTOSW condition.
For more information about protection schemes, refer to the
document.
Note
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
189
Alarm Troubleshooting
Clear the EXT Alarm