AUTOSW-UNEQ-SNCP (VCMON-HP)
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: VCMON-HP
The Automatic UPSR Switch Caused by an Unequipped condition indicates that an HP-UNEQ alarm caused
automatic UPSR protection switching to occur (see the
). If the UPSR ring is configured
for revertive switching, it reverts to the working path after the fault clears.
Class 1 laser product.
Statement 1008
Warning
Class 1M laser radiation when open. Do not view directly with optical instruments.
Statement 1053
Warning
Invisible laser radiation could be emitted from the end of the unterminated fiber cable or connector.
Do not stare into the beam directly with optical instruments. Viewing the laser output with certain
optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm
could pose an eye hazard.
Statement 1056
Warning
Use of controls, adjustments, or performing procedures other than those specified could result in
hazardous radiation exposure.
Statement 1057
Warning
This condition is only reported if the SNCP is set up for revertive switching.
Note
Clear the AUTOSW-UNEQ-SNCP (VCMON-HP) Condition
SUMMARY STEPS
1.
Complete the
Clear the HP-UNEQ Alarm, on page 232
procedure.
DETAILED STEPS
Complete the
Clear the HP-UNEQ Alarm, on page 232
procedure.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
141
Alarm Troubleshooting
AUTOSW-UNEQ-SNCP (VCMON-HP)