OTDR-HYBRID-SCAN-IN-PROGRESS-RX
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Objects: PPM
The Optical Time Domain Reflectometer (OTDR) Hybrid Scan In Progress RX condition occurs when a
hybrid OTDR scan starts in the RX direction.
Clear the OTDR-HYBRID-SCAN-IN-PROGRESS-RX Alarm
Step 1
This alarm is cleared automatically when the hybrid OTDR scan in the RX direction is complete.
Step 2
Alternatively, stop the scan by navigating to:
Maintenance
->
DWDM
->
OTDR
; select the side where the scan is ongoing
and click
Cancel
. The scan is stopped on both the sides.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
OTDR-HYBRID-SCAN-IN-PROGRESS-TX
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Objects: PPM
The Optical Time Domain Reflectometer (OTDR) Hybrid Scan In Progress TX condition occurs when a
hybrid OTDR scan starts in the TX direction.
Clear the OTDR-HYBRID-SCAN-IN-PROGRESS-TX Alarm
Step 1
This alarm is cleared automatically when the hybrid OTDR scan in the TX direction is complete.
Step 2
Alternatively, stop the scan by navigating to:
Maintenance
->
DWDM
->
OTDR
; select the side where the scan is ongoing
and click
Cancel
. The scan is stopped on both the sides.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
OTDR-ORL-THRESHOLD-EXCEEDED-RX
Default Severity: Minor (MN)
Logical Object: EQUIPMENT
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
335
Alarm Troubleshooting
OTDR-HYBRID-SCAN-IN-PROGRESS-RX