If the alarm does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
OTDR-ORL-TRAINING-IN-PROGRESS-TX
Default Severity: NA
Logical Object: EQUIPMENT
The OTDR-ORL-TRAINING-IN-PROGRESS-TX alarm is raised if the Optical Return Loss (ORL) is started
in the fast mode on the Tx side.
Clear the OTDR-ORL-TRAINING-IN-PROGRESS-TX Alarm
Wait until ORL training is completed in the Tx side. ORL training takes 10 seconds.
If the alarm does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
OTDR-OTDR-TRAINING-FAILED-RX
Default Severity: NA
Logical Object: EQUIPMENT
The OTDR-OTDR-TRAINING-FAILED-RX alarm is raised if the training phase cannot find valid calibration
data.
Clear the OTDR-OTDR-TRAINING-FAILED-RX Alarm
Execute the training scan in the RX direction.
If the scan shows high reflections, clean the connectors where the reflections are too high or change the
corresponding patchcords.
Note
If the alarm does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
338
Alarm Troubleshooting
OTDR-ORL-TRAINING-IN-PROGRESS-TX