Description
Error/Warning Message
Error/Warning
ID
Select the correct payload.
The time slot selected does not match the payload.
EID-5220
Select the correct payload.
The ODU-1 selected does not match the payload.
EID-5221
Refer to the error message text.
Deleting the following OCH TRAIL circuit(s) will
cause the Layer2 services (SVLAN, EVC and MPLS
TP Tunnel) provisioned on them to go PARTIAL.
WID-5221
Refer to the error message text.
This platform does not support power monitoring
thresholds.
EID-6000
Check whether all the cross-connect
cards are installed and working.
One of the XC cards has failures or is missing.
EID-6001
Unlock the cross-connect card.
One of the XC cards is locked.
EID-6002
Enter a new ID for the ring.
The OSC termination could not be created. This ring
ID is already assigned.
EID-6003
Remove the BLSR from the node and
continue with the reset procedure.
A system reset cannot be performed while a BLSR ring
is provisioned on the node.
EID-6004
Refer to the error message text.
The timing references could not be assigned. - Only
two DS1 or BITS interfaces can be specified. - DS1
interfaces cannot be retimed and used as a reference. -
BITS-2 is not supported on this platform.
EID-6005
Refer to the error message text.
The timing references could not be assigned. - An NE
reference can only be used if the timing mode is LINE.
- A BITS reference can only be used if the timing mode
is not LINE. - A Line reference can only be used if the
timing mode is not EXTERNAL.
EID-6006
Refer to the error message text.
SF BER and SD BER are not provisionable on the
protect line of a protection group.
EID-6008
Refer to the warning message text.
If autoadjust GFP buffers is disabled, GFP buffers
available must be set to an appropriate value based on
the distance between the circuit endpoints.
WID-6009
Refer to the warning message text.
If auto detection of credits is disabled, credits available
must be set to a value less than or equal to the number
of receive credits on the connected FC endpoint.
WID-6010
Refer to the warning message text.
Ingress idle filtering should be turned off only when
required to operate with non-Cisco Fibre
Channel/FICON-over-SONET equipment.
WID-6011
You cannot change the timing
configuration on this port unless the
circuits on this port are deleted.
The retiming configuration could not be changed
because there are circuits on this port.
EID-6012
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
533
Error Messages
Error Messages Reference