If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
APS-NO-RESPONSE
Default Severity: Minor (MN), Service Affecting (SA)
Logical Object: ODU
The APS-NO-RESPONSE alarm is raised when the requested or bridge signals of a SNC protection do not
match.
Clear the APS-NO-RESPONSE Alarm
Verify that the requested and bridge signals of SNC protection match.
If the alarm does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
APS-PROV-MISM
Default Severity: Minor (MN), Non-Service Affecting (NSA)
Logical Object: ODU
The APS-PROV-MISM alarm is raised when the SNC protection types on the near end and far end near are
incompatible.
Clear the APS-PROV-MISM Alarm
Verify that the near end and far end SNC protection types match.
If the alarm does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
AS-CMD
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
126
Alarm Troubleshooting
APS-NO-RESPONSE