Step 6
Select
Set Node ID
from the shortcut menu.
Step 7
In the Edit Node ID dialog box, enter the new ID. The Node ID is the number in parentheses after the Node Name.
Step 8
Click
OK.
Verify Node Visibility for Other Nodes
SUMMARY STEPS
1.
Log into a node on the network.
2.
In node view, click the
Provisioning
>
BLSR
tabs.
3.
Highlight a BLSR.
4.
Click
Ring Map
.
5.
In the BLSR Ring Map window, verify that each node in the ring appears on the ring map with a node ID
and IP address.
6.
Click
Close
.
DETAILED STEPS
Step 1
Log into a node on the network.
Step 2
In node view, click the
Provisioning
>
BLSR
tabs.
Step 3
Highlight a BLSR.
Step 4
Click
Ring Map
.
Step 5
In the BLSR Ring Map window, verify that each node in the ring appears on the ring map with a node ID and IP address.
Step 6
Click
Close
.
Protection Switching, Lock Initiation, and Clearing
The following sections give instructions for port, ring, and span switching and switch-clearing commands, as
well as lock-ons and lockouts.
Initiate a 1+1 Protection Port Force Switch Command
The following sections give instructions for port switching and switch-clearing commands.
SUMMARY STEPS
1.
In node view (single-shelf mode) or shelf view (multishelf mode), click the
Maintenance
>
Protection
tabs.
2.
In the Protection Groups area, select the protection group with the port you want to switch.
3.
In the Selected Groups area, select the port belonging to the card you are replacing. You can carry out
this command for the working or protect port. For example, if you need to replace the card with the
Protect/Standby port, click this port.
4.
In the Switch Commands area, click
Force
.
5.
Click
Yes
in the Confirm Force Operation dialog box.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
443
Alarm Troubleshooting
Verify Node Visibility for Other Nodes