2 Parameters
2.2 List of parameters
SINAMICS G130/G150
950
List Manual (LH2), 07/2016, A5E03263479A
Description:
Sets the velocity limit for the SSM feedback signal to detect standstill (n < nx).
When this limit value is undershot, the signal "SSM feedback signal active" (SGA n < n_x) is set.
For p9568 = 0, the value in p9546 is also applicable for SAM/SBR.
Caution:
The following applies for p9506 = 3:
The "SAM/SBR" function is deactivated if the selected threshold value is undershot.
Note:
F-DO: Failsafe Digital Output / SGA: Safety-related output
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SBR: Safe Brake Ramp (safe brake ramp monitoring)
SSM: Safe Speed Monitor (safety-related feedback signal from the velocity monitoring) / SGA n < nx: Safety-related
output n < nx
Description:
Sets the velocity hysteresis for the SSM feedback signal to detect standstill (n < nx).
Dependency:
Refer to: C01711
Note:
The velocity hysteresis is effective only if the function is enabled (p9501.16 = 1).
The parameter is included in the crosswise data comparison of the two monitoring channels.
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
Description:
Sets the velocity hysteresis for the SSM feedback signal to detect standstill (n < nx).
Dependency:
Refer to: C01711
Note:
The velocity hysteresis is effective only if the function is enabled (p9501.16 = 1).
The parameter is included in the crosswise data comparison of the two monitoring channels.
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
p9546
SI Motion SSM (SGA n < nx) velocity limit (CU) / SI Mtn SSM v_limCU
VECTOR_G (Safety
rot)
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
2823
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [rpm]
1000000.00 [rpm]
20.00 [rpm]
p9547
SI Motion SSM (SGA n < nx) velocity hysteresis (CU) / SI Mtn SSM hyst CU
VECTOR_G
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
2823
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.0010 [mm/min]
500.0000 [mm/min]
10.0000 [mm/min]
p9547
SI Motion SSM (SGA n < nx) velocity hysteresis (CU) / SI Mtn SSM hyst CU
VECTOR_G (Safety
rot)
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
2823
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.0010 [rpm]
500.0000 [rpm]
10.0000 [rpm]
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......