SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
489
2 Parameters
2.2 List of parameters
For p1982 = 2:
This is used for synchronous motor with motor encoder with absolute data to check this data.
With p1982 = 2, each time the pulses are enabled it is checked whether the absolute position supplied from the
encoder does not exceed a deviation of 45 degrees to the identified pole wheel position.
Not possible for separately excited synchronous motors.
Dependency:
Refer to: p0325, p0329, p1980, r1984, r1985, r1987, p1990
Note:
For encoderless operation, the pole position identification routine is selected with p1780.6
Description:
Displays the angular difference between the actual electrical commutation angle and the angle determined by the
pole position identification.
Dependency:
Refer to: p0325, p0329, p1980, p1982, r1985, r1987, p1990
Note:
PolID: Pole position identification
When the pole position identification routine is executed several times using p1983, the spread of the measured
values can be determined using this value. At the same position, the spread should be less than 2 degrees electrical.
Description:
Displays the saturation characteristic of the pole position identification routine (saturation technique).
Displays the current characteristic of the pole position identification routine (elasticity technique).
Dependency:
Refer to: p0325, p0329, p1980, p1982, r1984, r1987, p1990
Note:
PolID: Pole position identification
Regarding the saturation technique:
The values for the characteristic of the last saturation-based pole position identification routine are output every 1 ms
in order to record signals (e.g. trace).
Description:
Displays the trigger characteristic of the pole position identification routine.
The values for the characteristic of the last pole position identification routine are output every 1 ms in order to record
signals (e.g. trace).
The values for trigger characteristic and saturation characteristic are always output in synchronism from a time
perspective.
Dependency:
Refer to: p0325, p0329, p1980, p1982, r1984, r1985, p1990
Note:
PolID: Pole position identification
The following information and data can be taken from the trigger characteristic.
- the value -100% marks the angle at the start of the measurement.
- the value +100 % marks the commutation angle determined from the pole position identification routine.
r1984
PolID angular difference / PolID ang diff
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [°]
- [°]
- [°]
r1985
PolID saturation curve / PolID sat_char
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r1987
PolID trigger characteristic / PolID trig_char
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......