2 Parameters
2.2 List of parameters
SINAMICS G130/G150
744
List Manual (LH2), 07/2016, A5E03263479A
Description:
Sets the mode-dependent properties for energy-saving.
Index:
[0] = Reserved
[1] = Mode 2
Note:
Pe: PROFIenergy profiles
Description:
Display and binector output for the state display PROFIenergy energy saving active or inactive.
Note:
Bit 0 and bit 1 are inverse of one another.
Pe: PROFIenergy profiles
Description:
Sets the signal source to set in the PROFIdrive state S1 "switching-on inhibited".
Dependency:
Refer to: r5613
Note:
Pe: PROFIenergy profiles
Description:
Sets the phase shift of the second system with respect to the first system for the Motor Module for a 12-pulse gating
unit.
Value:
0:
Shift by +30 °
1:
Shift by -30 °
2:
Shift by 0 °
3:
Shift by +90 °
p5612[0...1]
Pe energy-saving properties mode-dependent / Pe properties mod
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Communications
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
[0]
0110
bin
[1] 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Reserved
Yes
No
-
r5613.0...1
CO/BO: Pe energy-saving active/inactive / Pe save act/inact
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
2382
P-Group:
Communications
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Pe active
Yes
No
-
01
Pe inactive
Yes
No
-
p5614
BI: Pe set switching-on inhibited signal source / Pe sw-on_inh s_src
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2382
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p6397
Motor Module phase shift second system / MM ph_sh 2nd sys
VECTOR_G
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
Converter
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 8
0
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......