Description:
Sets the bidirectional digital inputs/outputs as an input or output.
Notice:
Regarding the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note:
DI/DO: Bidirectional Digital Input/Output
Description:
Displays the access authority at the digital outputs.
Bit = 1:
The control has access authority to the digital output via PROFIBUS or direct access.
Bit = 0:
The drive has access authority to the digital output or the digital input/output is not set as digital output or is not
available.
Dependency:
Refer to: p0728, p0738, p0739, p0740, p0741, p0742, p0743, p0744, p0745, r0747, p0748
Notice:
Regarding the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note:
The DI/DO must be connected as output (p0728).
DI/DO: Bidirectional Digital Input/Output
p0728
CU set input or output / CU DI or DO
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
2119, 2030,
2031, 2130, 2131, 2132, 2133
P-Group:
Commands
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-
-
0000 0000 0000 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
08
DI/DO 8 (X122.9/X121.7)
Output
Input
-
09
DI/DO 9 (X122.10/X121.8)
Output
Input
-
10
DI/DO 10 (X122.12/X121.10)
Output
Input
-
11
DI/DO 11 (X122.13/X121.11)
Output
Input
-
12
DI/DO 12 (X132.9/X131.1)
Output
Input
-
13
DI/DO 13 (X132.10/X131.2)
Output
Input
-
14
DI/DO 14 (X132.12/X131.4)
Output
Input
-
15
DI/DO 15 (X132.13/X131.5)
Output
Input
-
r0729
CU digital outputs access authority / CU DO acc_auth
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
2030, 2031,
2130, 2131, 2132, 2133
P-Group:
Commands
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
08
DI/DO 8 (X122.9/X121.7)
High
Low
-
09
DI/DO 9 (X122.10/X121.8)
High
Low
-
10
DI/DO 10 (X122.12/X121.10)
High
Low
-
11
DI/DO 11 (X122.13/X121.11)
High
Low
-
12
DI/DO 12 (X132.9/X131.1)
High
Low
-
13
DI/DO 13 (X132.10/X131.2)
High
Low
-
14
DI/DO 14 (X132.12/X131.4)
High
Low
-
15
DI/DO 15 (X132.13/X131.5)
High
Low
-
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......