3
F
unction
d
iag
ram
s
3.12
Safety Integrated
TM54F
SIN
A
MIC
S
G130
/G15
0
12
22
List
Manual (L
H2)
, 07
/2016
, A5E032634
79A
F
ig.
3
-110
29
07 – Exten
ded
F
unction
s
a
ssi
gnmen
t (F-DO
0
…
F
-DO
3)
- 2907 -
Function diagram
8
7
6
5
4
3
2
1
DO: TM54F_MA, TM54F_SL
SINAMICS
06.07.15 V04.08.00
SI TM54F - Extended Functions assignment (F-DO 0 ... F-DO 3)
fp_2907_51_eng.vsd
p10000 (12.00 ms)
F-DO 0
[2895.8]
[2895.8]
[2895.8]
[2895.8]
F-DO 3
F-DO 2
F-DO 1
SI F-DO 0 S_src
p10042[0]
<1> If one input is not connected to a
signal source, this input is set to
HIGH (default setting).
Exception:
If all outputs are not connected to
a signal source, the output signal
is 0.
&
&
&
&
SI F-DO 0 S_src
p10042[1]
SI F-DO 0 S_src
p10042[2]
SI F-DO 0 S_src
p10042[3]
SI F-DO 0 S_src
p10042[4]
SI F-DO 0 S_src
p10042[5]
1
4
3
2
5
6
SI F-DO 1 S_src
p10043[0]
SI F-DO 1 S_src
p10043[1]
SI F-DO 1 S_src
p10043[2]
SI F-DO 1 S_src
p10043[3]
SI F-DO 1 S_src
p10043[4]
SI F-DO 1 S_src
p10043[5]
1
4
3
2
5
6
1
4
3
2
5
6
SI F-DO 2 S_src
p10044[1]
SI F-DO 2 S_src
p10044[2]
SI F-DO 2 S_src
p10044[3]
SI F-DO 2 S_src
p10044[4]
SI F-DO 2 S_src
p10044[5]
SI F-DO 2 S_src
p10044[0]
1
4
3
2
5
6
SI F-DO 3 S_src
p10045[1]
SI F-DO 3 S_src
p10045[2]
SI F-DO 3 S_src
p10045[3]
SI F-DO 3 S_src
p10045[4]
SI F-DO 3 S_src
p10045[5]
SI F-DO 3 S_src
p10045[0]
<1>
<1>
<1>
<1>
[2905.8]
[2905.8]
[2905.8]
[2905.8]
3:
Drive group 1 SS2 active
2:
Drive group 1 SS1 active
1:
Drive group 1 pulses suppressed
4:
Drive group 1 SOS active
5:
Drive group 1 SLS active
7:
Drive group 1 safe state
0:
No function
9:
Drive group 1 internal event
8:
Drive group 1 SOS selected
6:
Drive group 1 SSM feedback signal active
[2905.8]
[2905.8]
[2905.8]
[2905.8]
[2906.8]
257: Drive group 2 pulses suppressed
[2905.8]
[2905.8]
[2905.8]
[2905.8]
[2905.8]
771: Drive group 4 SS2 active
770: Drive group 4 SS1 active
769: Drive group 4 pulses suppressed
772: Drive group 4 SOS active
773: Drive group 4 SLS active
775: Drive group 4 Safe state
777: Drive group 4 internal event
776: Drive group 4 SOS selected
774: Drive group 4 SSM feedback signal active
[2905.8]
[2905.8]
[2905.8]
[2905.8]
[2906.8]
10: Drive group 1 active SLS stage bit 0
11: Drive group 1 active SLS stage bit 1
12: Drive group 1 SDI positive active
[2905.8]
[2905.8]
[2905.8]
[2905.8]
[2906.8]
13: Drive group 1 SDI negative active
[2905.8]
271: Drive group 2 active SLP stage
780: Drive group 4 SDI positive active
781: Drive group 4 SDI negative active
[2905.8]
[2905.8]
778: Drive group 4 active SLS stage bit 0
778: Drive group 4 active SLS stage bit 1
[2905.8]
513: Drive group 3 pulses suppressed
[2905.8]
[2906.8]
527: Drive group 3 active SLP stage
782: Drive group 4 SLP active
[2905.8]
15: Drive group 1 active SLP stage
[2905.8]
14: Drive group 1 SLP active
[2905.8]
783: Drive group 4 active SLP stage
[2905.8]
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......