Note:
Synchronism is reached (r3819.2 = 1), if the AND logic operation of the results from the phase measurement (p3813)
and voltage measurement (p3815) is fulfilled.
For voltage manipulated quantity margin (reserve) of the drive converter, the amplitude difference (r3814) between
the setpoint and actual value is controlled (corrected) to zero.
Description:
Displays the status word for the line-drive synchronization.
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 1st value pair of the friction characteristic.
Dependency:
Refer to: p3830, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 2nd value pair of the friction characteristic.
Dependency:
Refer to: p3831, p3845
r3819.0...7
CO/BO: Sync-line-drive status word / Sync ZSW
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
7020
P-Group:
Functions
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Sync-line-drive enabled
Yes
No
-
02
Sync-line-drive synchronism reached
Yes
No
-
03
Sync-line-drive synchronizing error
Yes
No
-
05
Sync-line-drive frequency measurement
active
Yes
No
-
06
Sync-line-drive phase control active
Yes
No
-
07
Sync-line-drive without drive
Yes
No
-
p3820[0...n]
Friction characteristic value n0 / Friction n0
VECTOR_G (n/M)
Can be changed:
T
Calculated:
CALC_MOD_LIM_REF
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
7010
P-Group:
Functions
Unit group:
3_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [rpm]
210000.00 [rpm]
15.00 [rpm]
p3821[0...n]
Friction characteristic value n1 / Friction n1
VECTOR_G (n/M)
Can be changed:
T
Calculated:
CALC_MOD_LIM_REF
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
7010
P-Group:
Functions
Unit group:
3_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [rpm]
210000.00 [rpm]
30.00 [rpm]
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......