SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
745
2 Parameters
2.2 List of parameters
4:
Shift by -90 °
5:
Shift by +120 °
6:
Shift by -120 °
7:
Shift by +150 °
8:
Shift by -150 °
Dependency:
Refer to: p7003
Notice:
The parameter is only evaluated if p7003 = 2.
Note:
For p6397 = 0 the following applies: The second systems leads for a positive direction of rotation.
For p6397 = 1 the following applies: The second systems lags for a positive direction of rotation.
Description:
Sets the smoothing of the flux orientation of the voltage model for a separately excited synchronous motor.
Description:
Offset voltage between phases L1 and L2 for the Voltage Sensing Module (VSM). The value is automatically
determined with the drive switched-off and stationary when the offset calculation is enabled. The last determined
value is saved if the offset calculation is inhibited. If the offset calculation is inhibited, then a fixed value can also be
entered here.
Dependency:
Refer to: p6903
Note:
Offset calibration is only automatically activated if the resulting motor voltage is less than 1% of the rated voltage.
Description:
Offset voltage between phases L2 and L3 for the Voltage Sensing Module (VSM). The value is automatically
determined with the drive switched-off and stationary when the offset calculation is enabled. The last determined
value is saved if the offset calculation is inhibited. If the offset calculation is inhibited, then a fixed value can also be
entered here.
Dependency:
Refer to: p6903
Note:
Offset calibration is only automatically activated if the resulting motor voltage is less than 1% of the rated voltage.
p6700[0...n]
Voltage model angle smoothing / U_mod ang smooth
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
100 [ms]
0 [ms]
p6870[0...n]
VSM offset voltage u1 - u2 / VSM offset u1 - u2
VECTOR_G (n/M)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
p0150
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-100.000 [V]
100.000 [V]
0.000 [V]
p6871[0...n]
VSM offset voltage u2 - u3 / VSM offset u2 - u3
VECTOR_G (n/M)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
p0150
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-100.000 [V]
100.000 [V]
0.000 [V]
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......