Description:
Setting to enable the function "Safe Cam" (SCA).
Dependency:
Refer to: p9501
Refer to: F01686
Note:
The "Safe Cam" function (SCA) can either be enabled using p9501 or p9503.
SCA: Safe Cam / SN: Safe software cam
Description:
Sets the modulo value in degrees for rotary axes of the "Safe position" function.
This modulo value is taken into account when safely referencing as well as when transferring the safe position via
PROFIsafe when the absolute position is enabled.
The value should be set, so that it is precisely at 2^n revolutions, so that when the range that can be represented (+/-
2048) overflows, this does not cause the position actual value to jump.
The modulo function is deactivated for a value = 0.
p9503
SI Motion SCA (SN) enable (Control Unit) / SI Mtn SCA enab
VECTOR_G
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Enable SCA1 (SN1)
Enable
Inhibit
-
01
Enable SCA2 (SN2)
Enable
Inhibit
-
02
Enable SCA3 (SN3)
Enable
Inhibit
-
03
Enable SCA4 (SN4)
Enable
Inhibit
-
04
Enable SCA5 (SN5)
Enable
Inhibit
-
05
Enable SCA6 (SN6)
Enable
Inhibit
-
06
Enable SCA7 (SN7)
Enable
Inhibit
-
07
Enable SCA8 (SN8)
Enable
Inhibit
-
08
Enable SCA9 (SN9)
Enable
Inhibit
-
09
Enable SCA10 (SN10)
Enable
Inhibit
-
10
Enable SCA11 (SN11)
Enable
Inhibit
-
11
Enable SCA12 (SN12)
Enable
Inhibit
-
12
Enable SCA13 (SN13)
Enable
Inhibit
-
13
Enable SCA14 (SN14)
Enable
Inhibit
-
14
Enable SCA15 (SN15)
Enable
Inhibit
-
15
Enable SCA16 (SN16)
Enable
Inhibit
-
16
Enable ESCA17 (SN17)
Enable
Inhibit
-
17
Enable SCA18 (SN18)
Enable
Inhibit
-
18
Enable SCA19 (SN19)
Enable
Inhibit
-
19
Enable SCA20 (SN20)
Enable
Inhibit
-
20
Enable SCA21 (SN21)
Enable
Inhibit
-
21
Enable SCA22 (SN22)
Enable
Inhibit
-
22
Enable SCA23 (SN23)
Enable
Inhibit
-
23
Enable SCA24 (SN24)
Enable
Inhibit
-
24
Enable SCA25 (SN25)
Enable
Inhibit
-
25
Enable SCA26 (SN26)
Enable
Inhibit
-
26
Enable SCA27 (SN27)
Enable
Inhibit
-
27
Enable SCA28 (SN28)
Enable
Inhibit
-
28
Enable SCA29 (SN29)
Enable
Inhibit
-
29
Enable SCA30 (SN30)
Enable
Inhibit
-
p9505
SI Motion SP modulo value (Control Unit) / SI mtn SP mod CU
VECTOR_G
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [°]
737280 [°]
0 [°]
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......