2 Parameters
2.2 List of parameters
SINAMICS G130/G150
730
List Manual (LH2), 07/2016, A5E03263479A
Note:
The identifier of a Technology Extension comprises a maximum of 8 characters plus separator.
TEC: Technology Extension
Description:
Displays the total length of the GUIDs of the Technology Extensions installed on this drive object.
Dependency:
Refer to: r4950, r4951, r4955, p4956, r4957, r4958, r4959, r4960
Note:
The GUID of a Technology Extension comprises 16 characters plus 1 character major information plus 1 character,
minor information.
GUID: Globally Unique IDentifier
TEC: Technology Extension
Description:
Displays the identifier of the Technology Extensions installed on this drive object.
r4955[0...8]: Identifier of Technology Extension 1
r4955[9...17]: Identifier of Technology Extension 2, ...
Dependency:
Refer to: r4950, r4951, r4952, p4956, r4957, r4958, r4959, r4960
Notice:
If there is no Technology Extension, then it is not possible to access an index.
Note:
TEC: Technology Extension
Description:
Setting to activate the Technology Extensions installed on this drive object.
r4956[0]: Activation of Technology Extension 1
r4956[1]: Activation of Technology Extension 2, ...
Value:
0:
Technology Extension inactive
1:
Technology Extension active
Dependency:
Refer to: r4950, r4951, r4952, r4955, r4957, r4958, r4959, r4960
Notice:
If there is no Technology Extension, then it is not possible to access an index.
Note:
TEC: Technology Extension
r4952
TEC DO-specific GUID total length / TEC DO GUID length
All objects
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
OEM range
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 288
-
r4955[0...n]
TEC DO-specific identifier / TEC DO ident
All objects
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned8
Dyn. index:
r4951
Func. diagram:
-
P-Group:
OEM range
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p4956[0...n]
TEC DO-specific activation / TEC DO act
All objects
Can be changed:
C1, T
Calculated:
-
Access level:
4
Data type:
Integer16
Dyn. index:
r4950
Func. diagram:
-
P-Group:
OEM range
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......