SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1867
4 Faults and alarms
4.2 List of faults and alarms
F35001
TM54F: Parameter value invalid
Message value:
%1
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Drive object:
B_INF, TM54F_MA, TM54F_SL, VECTOR_G
Component:
None
Propagation:
GLOBAL
Reaction:
NONE
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The functionality of Safety Basic Functions via TM54F is used.
TM54F has been incorrectly parameterized (incorrect parameter assignment).
Only the following signals may be parameterized:
- STO active
- SS1 active
- internal event
- safe state
Possible causes:
- p10024 ... p10038 not set to 0 or 255.
- p10039, p10042 ... p10045 use signals from Safety Extended Functions.
Fault value (r0949, interpret binary):
Bits 0 ... 3 specifies for which drive group an illegal F-DI was parameterized:
Bit 0 = 1: drive group 1 error
Bit 1 = 1: drive group 2 error
Bit 2 = 1: drive group 3 error
Bit 3 = 1: drive group 4 error
Bits 4 ... 7 specifies for which F-DOs incorrect links were specified:
Bit 4 = 1: F-DO 0 error (p10042)
Bit 5 = 1: F-DO 1 error (p10043)
Bit 6 = 1: F-DO 2 error (p10044)
Bit 7 = 1: F-DO 3 error (p10045)
Remedy:
- check the setting of the fail-safe digital inputs (F-DI) for the Safety Extended Functions - and set to a value of 0 or
255 (p10024 ... p10039).
- check the setting of the signal sources for the fail-safe digital outputs (F-DO) and if necessary, correct (p10042 ...
p10045).
Note:
F-DI: Failsafe Digital Input
F-DO: Failsafe Digital Output
F35002
TM54F: Commissioning not possible
Message value:
%1
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Drive object:
B_INF, TM54F_MA, TM54F_SL, VECTOR_G
Component:
None
Propagation:
GLOBAL
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
The commissioning mode activation was rejected because at least one drive belonging to the TM54F is enabled for
operation.
Fault value (r0949, interpret decimal):
Drive object number of the first drive found without pulse suppression/power inhibit.
Remedy:
Withdraw the operating enable for the drive specified in the fault value.
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......