SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
759
2 Parameters
2.2 List of parameters
Description:
Ring buffer for faults and alarms that have occurred from power units connected in parallel (Motor Module, Active
Line Infeed, Voltage Sensing Module).
Displays the relative system runtime when the fault or alarm was withdrawn.
Dependency:
Refer to: r7100, r7101, r7102
Note:
The last fault case that occurred is documented in index 0.
The parameter is reset to 0 at POWER ON.
Description:
Displays the overload of the particular power unit in a parallel circuit configuration calculated using the I2t function.
The maximum value of all power units is displayed in r0036.
Description:
Displays the maximum inverter temperature in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[0].
Description:
Displays the maximum depletion layer temperature in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[1].
r7103[0...99]
Par_circuit ring buffer fault/alarm gone / F/A gone
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r7200[0...n]
Par_circuit power unit overload I2t / PU overload I2t
VECTOR_G (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r7201[0...n]
CO: Par_circuit power unit temperatures max. inverter / PU temp max inv
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r7202[0...n]
Par_circuit power unit temperatures max. depletion layer / PU TempMaxDepLayer
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......