SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
531
2 Parameters
2.2 List of parameters
Dependency:
Refer to: p2051, p2080, p2081, p2082, p2083
Note:
r2089 together with p2080 to p2084 forms five binector-connector converters.
Description:
Binector output for bit-serial interconnection of PZD1 (normally control word 1) received from the PROFIdrive
controller.
Note:
IF1: Interface 1
Description:
Binector output for bit-serial interconnection of PZD2 received from the PROFIdrive controller.
03
Bit 3
ON
OFF
-
04
Bit 4
ON
OFF
-
05
Bit 5
ON
OFF
-
06
Bit 6
ON
OFF
-
07
Bit 7
ON
OFF
-
08
Bit 8
ON
OFF
-
09
Bit 9
ON
OFF
-
10
Bit 10
ON
OFF
-
11
Bit 11
ON
OFF
-
12
Bit 12
ON
OFF
-
13
Bit 13
ON
OFF
-
14
Bit 14
ON
OFF
-
15
Bit 15
ON
OFF
-
r2090.0...15
BO: IF1 PROFIBUS PZD1 receive bit-serial / IF1 PZD1 recv bitw
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP,
VECTOR_G, B_INF,
TM31, TM120, TM150,
TB30, ENC
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
2468
P-Group:
Communications
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Bit 0
ON
OFF
-
01
Bit 1
ON
OFF
-
02
Bit 2
ON
OFF
-
03
Bit 3
ON
OFF
-
04
Bit 4
ON
OFF
-
05
Bit 5
ON
OFF
-
06
Bit 6
ON
OFF
-
07
Bit 7
ON
OFF
-
08
Bit 8
ON
OFF
-
09
Bit 9
ON
OFF
-
10
Bit 10
ON
OFF
-
11
Bit 11
ON
OFF
-
12
Bit 12
ON
OFF
-
13
Bit 13
ON
OFF
-
14
Bit 14
ON
OFF
-
15
Bit 15
ON
OFF
-
r2091.0...15
BO: IF1 PROFIdrive PZD2 receive bit-serial / IF1 PZD2 recv bitw
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP,
VECTOR_G, B_INF,
TM31, TM120, TM150,
TB30, ENC
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
2468
P-Group:
Communications
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Bit 0
ON
OFF
-
01
Bit 1
ON
OFF
-
02
Bit 2
ON
OFF
-
03
Bit 3
ON
OFF
-
04
Bit 4
ON
OFF
-
05
Bit 5
ON
OFF
-
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......