SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
443
2 Parameters
2.2 List of parameters
Description:
Sets the proportional gain of the d-current controller for the lower adaptation current range.
This value is automatically pre-set using p3900 or p0340 when commissioning has been completed.
Description:
Sets the integral time of the d-current controller.
Description:
Displays the actual output of the Isd current controller (flux-generating current, PI controller).
The value contains the proportional and integral components of the PI controller.
Description:
Displays the integral component of the Isd current controller (flux-generating current, PI controller).
Description:
Displays the limit value for the integral component of the Isd current controller.
p1720[0...n]
Current controller d axis p gain / Id_ctrl Kp
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, SESM,
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.000 100000.000
0.000
p1722[0...n]
Current controller d axis integral time / I_ctrl d-axis Tn
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, SESM,
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
1000.00 [ms]
2.00 [ms]
r1723
CO: Isd controller output / Isd_ctrl outp
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6714
P-Group:
Closed-loop control
Unit group:
5_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
p2001
Expert list:
1
Min Max
Factory
setting
- [Vrms]
- [Vrms]
- [Vrms]
r1724
Isd controller integral component / Isd_ctrl I_comp
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6714
P-Group:
Closed-loop control
Unit group:
5_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
p2001
Expert list:
1
Min Max
Factory
setting
- [Vrms]
- [Vrms]
- [Vrms]
r1725
Isd controller integral component limit / Isd_ctrl I_limit
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6714
P-Group:
Closed-loop control
Unit group:
5_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
p2001
Expert list:
1
Min Max
Factory
setting
- [Vrms]
- [Vrms]
- [Vrms]
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......