SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
487
2 Parameters
2.2 List of parameters
Description:
Displays the period number determined by the vibration test.
Index:
[0] = No. of periods of the low frequency
[1] = No. of periods of the high frequency
Dependency:
Refer to: p1959
Refer to: F07985
Description:
Displays the number of pulses determined during the vibration test.
Note:
A negative signal indicates an incorrect polarity of the encoder signal.
Description:
Sets the maximum flux setpoint to measure the saturation characteristic.
Description:
Displays the status to check and monitor the states of speed controller optimization.
r1972[0...1]
Speed_ctrl_opt vibration test number of periods determined / n_opt per_qty det
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r1973
Rotating measurement encoder test pulse number determined / n_opt puls no. det
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p1974
Speed_ctrl_opt saturation characteristic rotor flux maximum / n_opt rot_fl max
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
PMSM, SESM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
104 [%]
120 [%]
120 [%]
r1979.0...12
BO: Speed_ctrl_opt status / n_opt status
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Speed controller optimization activated
Yes
No
-
01
Speed controller optimization completed
Yes
No
-
02
Speed controller optimization interrupted
Yes
No
-
04
Enc test active
Yes
No
-
05
Saturation char. identification active
Yes
No
-
06
Moment of inertia identification active
Yes
No
-
07
Recalc. speed controller parameters active
Yes
No
-
08
Speed controller vibration test active
Yes
No
-
09
Magnetizing inductance adapt. active
Yes
No
-
10
Operation with encoder after encoderless
operation
Yes
No
-
11
q-leakage inductance identification
Yes
No
-
12
Moment of inertia estimator inhibited
Yes
No
-
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......