2 Parameters
2.2 List of parameters
SINAMICS G130/G150
486
List Manual (LH2), 07/2016, A5E03263479A
Description:
Displays the dynamic factor which is actually achieved for the vibration test
Dependency:
Refer to: p1959, p1967
Refer to: F07985
Note:
This dynamic factor only refers to the control mode of the speed controller set in p1960.
Description:
Displays the determined moment of inertia of the drive.
After it has been determined, the value is transferred to p0341, p0342.
Dependency:
IEC drives (p0100 = 0): unit kg m^2
NEMA drives (p0100 = 1): unit lb ft^2
Refer to: p0341, p0342, p1959
Refer to: F07984
Description:
Displays the vibration frequencies determined by the vibration test.
Index:
[0] = Frequency low
[1] = Frequency high
Dependency:
Refer to: p1959
Refer to: F07985
Description:
Displays the standard deviations of the vibration frequencies determined by the vibration test
Index:
[0] = Standard deviation of low frequency
[1] = Standard deviation of high frequency
Dependency:
Refer to: p1959
Refer to: F07985
r1968
Speed_ctrl_opt dynamic factor actual / n_opt dyn_fact act
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r1969
Speed_ctrl_opt moment of inertia determined / n_opt M_inert det
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
25_1
Unit selection:
p0100
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [kgm²]
- [kgm²]
- [kgm²]
r1970[0...1]
Speed_ctrl_opt vibration test vibration frequency determined / n_opt f_vib det
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
r1971[0...1]
Speed_ctrl_opt vibration test standard deviation determined / n_opt std_dev det
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......