2 Parameters
2.2 List of parameters
SINAMICS G130/G150
164
List Manual (LH2), 07/2016, A5E03263479A
Note:
ZM: Zero mark
SMC: Sensor Module Cabinet
If a technique to determine the commutation information/data has not been selected (e.g. track C/D, Hall sensor), and
the encoder pulse number is an integer multiple of the pole number, then the following applies:
The track A/B is adjusted to match the magnetic position of the motor.
For bit 01, 02 (absolute encoder, multiturn encoder):
These bits can only be selected for EnDat encoders, SSI encoders or DRIVE-CLiQ encoders.
For bit 10 (DRIVE-CLiQ encoder):
This bit is only used for the large-scale integrated DRIVE-CLiQ encoders that provide their encoder data directly in
DRIVE-CLiQ format without converting this data. This bit is not, therefore, set for first-generation DRIVE-CLiQ
encoders.
For bit 12 (equidistant zero mark):
The zero marks occur at regular intervals (e.g. rotary encoder with 1 zero mark per revolution or linear encoder with
constant zero mark distance).
The bit activates monitoring of the zero mark distance (p0424/p0425, linear/rotary) or in the case of the linear
encoder with 1 zero mark and p0424 = 0 zero mark monitoring is activated.
For bit 13 (irregular zero mark):
The zero marks occur at irregular intervals (e.g. a linear scale with only 1 zero mark in the traversing range). The zero
mark distance is not monitored.
For bit 14 (distance-coded zero mark):
The distance (clearance) between two or several consecutive zero marks allows the absolute position to be
calculated.
For bit 15 (commutation with zero mark):
Only applicable for synchronous motors.
The function can be de-selected by priority via p0430.23.
For distance-coded zero marks, the following applies:
The phase sequence of the C/D track (if available) must be the same as the phase sequence of the encoder (A/B
track).
The phase sequence of the Hall signal (if available) must be the same as the phase sequence of the motor. Further,
the position of the Hall sensor must be mechanically adjusted to the motor EMF.
The fine synchronization is only started after two zero marks have been passed.
Description:
Settings for the basic encoder properties.
p0404[0...n]
Encoder configuration effective / Enc_config eff
ENC
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
EDS, p0140
Func. diagram:
4010, 4704
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Linear encoder
Yes
No
-
01
Absolute encoder
Yes
No
-
02
Multiturn encoder
Yes
No
-
03
Track A/B sq-wave
Yes
No
-
04
Track A/B sine
Yes
No
-
05
Track C/D
Yes
No
-
06
Hall sensor
Yes
No
-
08
EnDat encoder
Yes
No
-
09
SSI encoder
Yes
No
-
10
DRIVE-CLiQ encoder
Yes
No
-
11
Digital encoder
Yes
No
-
12
Equidistant zero mark
Yes
No
-
13
Irregular zero mark
Yes
No
-
14
Distance-coded zero mark
Yes
No
-
15
Commutation with zero mark (not ASM)
Yes
No
-
16
Acceleration
Yes
No
-
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......