Description:
Sets the stop response for the function "Safely Limited Position" (SLP).
Value:
0:
STOP A
1:
STOP B
2:
STOP C
3:
STOP D
4:
STOP E
10:
STOP A with delayed stop response when the bus fails
11:
STOP B with delayed stop response when the bus fails
12:
STOP C with delayed stop response when the bus fails
13:
STOP D with delayed stop response when the bus fails
14:
STOP E with delayed stop response when the bus fails
Index:
[0] = Limit value SLP1 (SE1)
[1] = Limit value SLP2 (SE2)
Dependency:
Refer to: p9534, p9535
Note:
In the extended sense, a bus failure should be seen here as a communication error in the control signals of the safety
functions (e.g. via PROFIsafe or TM54F).
SLP: Safely Limited Position
Description:
Sets the stop response for the function "Safely Limited Speed" (SLS).
These settings apply to the individual limit values for SLS.
In the case of encoderless motion monitoring (p9506/p9306 = 1, 3), only a value of 0 or 1 is permitted.
Value:
0:
STOP A
1:
STOP B
2:
STOP C
3:
STOP D
4:
STOP E
10:
STOP A with delayed stop response when the bus fails
11:
STOP B with delayed stop response when the bus fails
12:
STOP C with delayed stop response when the bus fails
13:
STOP D with delayed stop response when the bus fails
14:
STOP E with delayed stop response when the bus fails
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLS4
Dependency:
Refer to: p9331, p9380, p9563
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
In the extended sense, a bus failure should be seen here as a communication error in the control signals of the safety
functions (e.g. via PROFIsafe or TM54F).
SLS: Safely Limited Speed
p9362[0...1]
SI Motion SLP stop response (Motor Module) / SI mtn SLP stop MM
VECTOR_G
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 14
2
p9363[0...3]
SI Motion SLS stop response (Motor Module) / SI Mtn SLS Stop MM
VECTOR_G
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 14
2
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......