2 Parameters
2.2 List of parameters
SINAMICS G130/G150
1038
List Manual (LH2), 07/2016, A5E03263479A
Description:
Sets the drive group for the drives that are available.
A drive group is a combination of several drives with the same types of behavior.
Index:
[0] = Drive 1
[1] = Drive 2
[2] = Drive 3
[3] = Drive 4
[4] = Drive 5
[5] = Drive 6
Note:
If the basic functions are controlled via the TM54F, then within a drive group, only drives with basic functions or
drives with extended functions can be assigned.
Description:
Sets the actual Node Identifier (word 1, bit 0 ... 31) for the Motor/Hydraulic Modules.
Index:
[0] = Drive 1
[1] = Drive 2
[2] = Drive 3
[3] = Drive 4
[4] = Drive 5
[5] = Drive 6
Dependency:
Refer to: p10013, p10014
Note:
The Node Identifier (96 bit) is represented in the following 3 parameters.
p10012[0] word 1 (bit 0 ... 31) for Motor/Hydraulic Module 1
...
p10012[5] word 1 (bit 0 ... 31) for Motor/Hydraulic Module 6
p10013[0] word 2 (bit 32 ... 63) for Motor/Hydraulic Module 1
...
p10013[5] word 2 (bit 32 ... 63) for Motor/Hydraulic Module 6
p10014[0] word 3 (bit 64 ... 95) for Motor/Hydraulic Module 1
...
p10014[5] word 3 (bit 64 ... 95) for Motor/Hydraulic Module 6
Description:
Sets the actual Node Identifier (word 2, bit 32 ... 63) for the Motor/Hydraulic Modules.
Index:
[0] = Drive 1
[1] = Drive 2
[2] = Drive 3
p10011[0...5]
SI TM54F drive group assignment / SI drv_gr assign
TM54F_MA,
TM54F_SL
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
2892
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
1 4
1
p10012[0...5]
SI TM54F Motor/Hydraulic Module Node Identifier Word 1 / SI MM/HM Node ID 1
TM54F_MA,
TM54F_SL
Can be changed:
C2(95)
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p10013[0...5]
SI TM54F Motor/Hydraulic Module Node Identifier Word 2 / SI MM Node ID 2
TM54F_MA,
TM54F_SL
Can be changed:
C2(95)
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......